Releases Tagged: Masonry Slender Wall

Introduced the ability to specify negative values for the Full Area Wind Load (2025-06-17)

The following enhancements and fixes have been made (2025-05-19):

feature
  • Updated the maximum reinforcement checks to properly handle the net tensile strain provisions of TMS 402-22 Table 9.1.4 in preparation for IBC 2024 support. Note, at this time the Masonry Slender Wall module only supports tension-controlled designs (φ=0.9).

bugfix
  • Fixed an issue where the Steel Area Max Allow column on the Strength Design Results tab was not displaying values.

  • Revised the logic for the Steel Area Max Allow column on the Strength Design Results tab to better handle conditions for partially grouted walls, especially for walls with bar spacing greater than 48".

  • Resolved a bug in the printed calculation report that prevented the reinforcing limit check from displaying "PASS" when the check was satisfied.

Added a right-click context menu for easy expand/collapse of results tables as well as the ability to export or copy/paste of data from to Excel or CSV. (2025-04-10)

General (Case 131214)

4 months ago

Added right-click context menus to the Multiple Simple Beam module for quick expand/collapse of results tables, along with the ability to export or copy/paste data to Excel or CSV. 

As part of this update, the underlying context menu logic was refactored and standardized for improved consistency and maintainability across several other modules that already included similar functionality. (2025-04-04)